FireBOX GA
FireBOX GA
Self-extinguishing inline pre-filter
In the event that a burning ember is drawn into the fume extraction unit, there is the possibility that hot debris in the filters could ignite. Although any resultant fire would typically be retained within the fume extraction unit, this would cause significant damage and in extreme circumstances, the risk may extend beyond the extraction unit. For processes where such risks have been identified, additional protection in the form of an inline FireBOX is an additional precaution.
The built-in temperature controller can be set so that when a 10°C (18°F) temperature rise over the pre-set ambient temperature is detected, the FireBOX GA will activate the isolating valves and switch off the power to the extraction unit, suppressing the airflow to the FireBOX and reducing the fire. If the temperature rises another 10°C (18°F), the fire extinguisher will be activated.
Independent tests by Ordnance Testing Solutions Ltd found the FireBOX GA contains and suppresses fires consisting of burning polymer particulate. The FireBOX GA is designed for general applications and is not for use on metal-based applications. Please refer to the FireBOX MA or contact us to ensure you choose the right system.
Shipping Instructions – Dangerous Goods Classification
The Firebox product category (MA & GA) contains components that mean it has been classified as Dangerous goods under the Dangerous Goods Regulations.
The classification of the product falls under UN1044 – FIRE EXTINGUISHERS, CLASS 2.2 and will need addressing for transport via both Air and Sea. On the occasion that the product is to be moved via road freight then it is exempt from ADR Regulations for transport (Under Special Provision 594) and no further action is required.
For more information, please contact BOFA or your freight forwarder.
View the product video here.
Is this the system for you?
Let our knowledgeable team support you in choosing the most appropriate system for your requirements.


We offer a range of accessories for many of our units
Please refer to our accessories page for further information and then get in touch with our experts to define exactly what you need.

Key features of the FireBOX GA

DeepPleat DUO pre-filter

Reverse flow air (RFA) technology

Multi voltage sensing (MVS) unit

Patented technology

ProTECT service plan

SureCHECK quality standard
Datasheet correct at time of publishing. For specific applications, please contact us for details.